|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
Filename: TFS140X.doc version 1.2 24.11.2003 VI TELEFILTER Measurement condition Ambient temperature: Input power level: Source and load impedance: Terminating impedances * Input: Output: 25 0 50 99 103 2 Filter specification TFS 140X 1/5 C dBm || - 28.3 pF || - 27.2 pF Characteristics Remark: The reference level for the relative attenuation a rel of TFS140X is the minimum of the pass band attenuation amin. This value is defined as the insertion loss ae . The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the 20 dB filter attenuation level relative to the insertion loss a e. The frequency shift of the filter in the operating temperature range is not included in the production tolerance scheme Data Insertion loss Nominal frequency a e = amin typ. value 9 140 dB MHz max. limit 12 140,0 139,60 ... 140,40 fN 7,1 1 17 17,75 24 48 1 3 35 40 10 60 825 + 10 dB MHz MHz MHz dB MHz MHz MHz MHz dB dB dB dB deg p-p ns ns dBm fN Centre frequency fc (at ambient temperature) Pass band PB 0.2 17,6 18,5 21,8 24,8 a rel Amplitude ripple (peak to adjacent valley) within fN 7,2 MHz Bandwidth 1 dB 3 dB 35 40 dB dB 8,5 MHz 8,875 MHz 24 40 MHz MHz max. MHz MHz MHz MHz dB dB dB dB deg ns ns min. min. max. max. max. max. min. min. max. max. max. max. Relative attenuation fN ... fN fN 8,5 MHz ... fN 12 MHz ... fN fN fN 24 MHz ... fN Phase variation within PB 0,5 1,5 40 50 6 44 777 Group delay ripple within PB Absolute group delay within PB Input power level Operable temperature range Storage temperature range Temperature coefficient of frequency *) TCf - 40 C ... + 85 C - 40 C ... + 85 C -87 ppm/K The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference values only. Should there be additional questions, do not hesitate to ask for an application note or contact our design team. Generated: Checked / approved: Tele Filter GmbH Potsdamer Strae 18 D 14 513 Teltow / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: TFS140X.doc version 1.2 24.11.2003 VI TELEFILTER Construction and pin connection (All dimensions in mm) Filter specification TFS 140X 2/5 TFS 140X R13 Datecode 1 2 3 4 5 6 7 8 9 10 11 12 Ground Ground Ground Ground Output Output RF Return Ground Ground Ground Ground Input Input RF Return Date code: Year+week N 2001 P 2002 R 2003 ...... 50 test circuit L1 11 5 L2 Output 50 Ohm C1 Input 50 Ohm SAW C2 1,2,3,4,6,7,8,9,10,12 Tele Filter GmbH Potsdamer Strae 18 D 14 513 Teltow / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: TFS140X.doc version 1.2 24.11.2003 VI TELEFILTER Stability Characteristics Filter specification TFS 140X 3/5 After the following tests the filter shall meet the whole specification: 1. Shock: 500g, 18 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 -55 C to 125C / 30 min. each / 10 cycles DIN IEC 68 part 2 - 14 Test N 2. Vibration: 3. Change of temperature: 4. Resistance to solder heat (reflow):reflow possible: twice max.; for temperature conditions, please refer to the attached "Air reflow temperature conditions" on page 4; Packing Tape & Reel: DIN IEC 286 - 3, with exception of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters per reel: reel of empty components at start: reel of empty components at start including leader: trailer mm 1700 min 300 mm min 500 mm min 300 Tape (all dim en sions in mm ) W : 24 0,3 Po : 4 0,1 Do : 1,5 + 0,1 E : 1,75 0,1 F : 11,5 0,1 G (min) : 0,60 P2 : 2 0,1 P1 : 12 0,1 D1(min) : 1,5 Ao : 7,1 0,2 Bo : 13,9 0,2 Ct : 21,5 0,1 EMBOSSED CARR IER TAPE Do Po P2 E Ao F W D1 Ct Bo G P1 COVE R TAP E W2 Reel (all dimensions in mm): A : 330 24,40 +2,0 30,4 60 13 0,5/-0.2 A C N W1 : W2 (max) : N (min) C : : W1 The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape. Markings on the filters can be read if the upper side of the carrier tape is regarded with the sprocket holes on its right. Tele Filter GmbH Potsdamer Strae 18 D 14 513 Teltow / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: TFS140X.doc version 1.2 24.11.2003 VI TELEFILTER Filter specification TFS 140X 4/5 Air reflow temperature conditions 1st and 2nd air reflow profile Name: Temperature: Time: pre-heating periods 150 C - 170 C 60 sec. - 90 sec. main-heating periods over 200 C 20 sec. - 25 sec. peak temperature 255 C 5 C Chip-mount air reflow profile 260 240 220 200 180 temperature / C 160 140 120 100 80 60 40 20 0 0 20 40 60 80 100 120 time / sec. 140 160 180 200 220 240 Table for temperature vs. time during the air reflow process Tolerance of temperatures: 5 C time / sec. 0 10 20 30 40 50 60 70 80 90 100 110 120 130 temperature / C 23 34 46 60 80 103 121 134 143 150 154 156 158 159 time / sec. 140 150 160 170 180 190 195 200 205 210 215 220 230 240 temperature / C 160 161 164 170 180 205 230 255 230 205 180 165 140 120 Tele Filter GmbH Potsdamer Strae 18 D 14 513 Teltow / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: TFS140X.doc version 1.2 24.11.2003 VI TELEFILTER Filter specification TFS 140X 5/5 History Version 1.0 1.1 Reason of Changes generation of specification according to customer requirements group delay ripple changed absolute group delay added changed to filter specification terminating impedances added typical values added pass band added bandwidth for 1 dB, 3 dB, 35 dB changed relative attenuation changed Name E. Chilla E. Chilla Date 28.04.2003 21.04.2003 1.2 E. Chilla 24.11.2003 Tele Filter GmbH Potsdamer Strae 18 D 14 513 Teltow / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. |
Price & Availability of TFS140X |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |